Equilibrium Reactor Data

 

Use this window to specify equilibrium reactor options and limits.

 

Usage

 

Exclude Heat Balance

This option is only available if the Fixed Temperature thermal specification is selected on the Equilibrium Reactor Main Window. Check the box to indicate that no heat of reaction should be calculated.

 

Temperature Limits

The minimum and maximum temperatures allowed for the reactor calculations may be entered if the Fixed Duty thermal specification is selected on the Equilibrium Reactor Main Window.

 

Reaction Reference State

Click to select the reaction reference state.

 

Ideal Gas Enthalpy: Enthalpy is calculated using ideal gas enthalpy correlation at 298.15 K and 1 atm.

 

Reference Pressure: Enthalpy is calculated as per Thermodynamic set specified for the reactor. Vapor phase reactions consider 298.15 K &1atm pressure and liquid phase reactions consider 298.15 K & reactor outlet pressure as reference state.

 

How to get to this window

The Equilibrium Reactor Data window is accessed by pressing the Reactor Data button on the Equilibrium Reactor Main Window.

 

image\SML_LINE.gif

 

Equilibrium Reactor - Technical Information

Toolbar

OK and Cancel Buttons